XtremIO 3.0.3-11 Release

XtremIO 3.0.3-11 was just released and below is a list of the fixes. These can be found in the release notes for 3.0.3-11.

General Fixed Issues

  • SSD status check has a wrong timeout and may, in some rare cases of SSD failure, cause an unexpected service stop.
    • XIO-11168
  • In some rare cases, resetting a new SSD in the DAE causes an unexpected service stop.
    • XIO-10703
  • SSD insertion is detected by only one Storage Controller, and in some rare cases causes an unexpected service stop.
    • XIO-10667
  • Deleting a high number of snapshots or creating and deleting a snapshot of the same volume at the same time may cause an internal module restart that does not cause any high availability event.
    • XIO-10550
  • The System Manager module fails and restarts when the add-initiator command is sent to a non-existing Initiator Group.
    • XIO-10650
  • OpenSSL has been upgraded to openssl-1.0.1e-30.
  • OpenSSH has been upgraded to openssh-5.3p1-104.
  • HTTP TRACE method is disabled.
    • XIO-9196
  • Replacing an SSD without following the correct procedure causes the SSD replacement to fail with “SSD not initialized” and “SSD is not configured in any XDP group” alerts. The replaced SSD is not cleared from the repository.
    • XIO-9079
  • Fabric WWN is displayed as an initiator.
    • XIO-11050
    • XIO-5579
    • XIO-2912
  • In some rare cases a high volume of deletion I/O causes an increase in the latency.
    • XIO-10527
  • SCSI registration preempt with type change can cause an unexpected module restart.
    • XIO-11089
  • A “sense data” response is sent during registration conflict, even when the SCSI status is not “Check Condition”, which causes Emulex HBA to ignore the registration conflict.
    • XIO-10692

Upgrade and Cluster Hardware Upgrade Fixed Issues

  •  The create-snapshot command may receive a busy response if the cluster is going through OS upgrade.
    • XIO-10245
  • In some rare cases, issuing the read-reservation SCSI command after NDU to a registered path that was registered before the NDU, can cause the cluster’s state to appear as “unknown”. The cluster automatically recovers with no user intervention.
    • XIO-12127
  • SCSI reservations that are made during NDU cannot be released.
    • XIO-11722

High Availability Fixed Issues

  • In some rare cases, losing power on one InfiniBand Switch causes an unexpected service stop.
    • XIO-10252

UI and XMS Fixed Issues

  • XtremIO SNMP trap OID contains two redundant digits.
    • XIO-12530
  • Entering unsupported characters while modifying a password may cause the password to be unusable.
    • XIO-10800
  • SSH key based users are removed during the cluster maintenance.
    • XIO-11202
  • The severity of sys_ud_ssd_space_very_limited alert (Cluster capacity at 90%) has been changed to “Major” severity.
    • XIO-11262
  • The thresholds for free physical space alerts have been changed to:
  • Limited Free Space threshold : 15% (85% used)
  • Very Limited Free space: 10% (90% used)
  • No free space: 3% (97% used)
    • XIO-9387
  • Using RESTful API with External User (LDAP) can cause XMS unavailability. Using a local account for RESTful API prevents the issue.
    • XIO-9589
  • XMS recovery fails when the configuration has SSH key based users with public key longer than 2048 bytes.
    • XIO-8891
  • OpenLDAP authentication fails when “uniquememeber” is used as part of the group membership search.
    • XIO-9074
  • RESTful API requests to /api/json do not receive a proper response and time out.
    • XIO-11406
  • LDAP authentication fails when the user name contains special characters.
    • XIO-11015

Enhancements

  • Added the NAA identifier to the show-volumes command.
    • XIO-9071
  • The modify-cluster-passwords have been changed to allow changing the “xinstall” password. For changing the cluster’s passwords, refer to EMC KB 183472.
    • XIO-10119
  • Added command to clear SCSI reservations.
    • XIO-10338
  • Added a warning message and confirmation request to the clear-volumereservation command.
    • XIO-10706
  • A warning message and additional confirmation were added to the freshinstall command to prevent the installation of an existing cluster.
    • XIO-11815
  • Warning messages were added to the stop-cluster command.
    • XIO-11743
Advertisements

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out / Change )

Twitter picture

You are commenting using your Twitter account. Log Out / Change )

Facebook photo

You are commenting using your Facebook account. Log Out / Change )

Google+ photo

You are commenting using your Google+ account. Log Out / Change )

Connecting to %s